High Temperature Kinematic Viscosity Bath - by Koehler (from old Koehler Catalog)
Click here for the Latest Koehler Catalog !
| Specifications | |
- Conforms to ASTM D445, D2170, IP 71, 319, ISO 3104, DIN 51550, FTM 791-305
- Capacity: 6 glass capillary viscometers
- Dimensions: Depth [12" (30.5cm)] Capacity [7.6 gal. (28.8 l)]
- Bath Medium: high temperature silicone heat transfer fluid is recommended
- Viscometer Ports: Round [2" (51mm) dia.] Rectangular [1.75 x 2" (44.5 x 50.8 cm)]
- Electrical Requirements: [115V 50/60 Hz, Single Phase, 13.9 Amp] [220-240V 50/60 Hz,
Single Phase, 7.2 Amp]
- Included accessories: Port covers, stainless steel (6)
- Dimensions: (l x w x h) 14.5" x 14.5" x 36.5" (36.8 x 36.8 x 92.7 cm) 13.6 cu. ft. for
shipping
- Weight: 68 lbs. (30.8 kg) Shipping Weight: 90 lbs. (40.8 kg)
|  |
| Key Features |
- High accuracy temperature control with digital setpoint and display
- Test temperature range to 450°F (232°C)
- Viscometer port options
- Continuous heat circuit for rapid warm-up
- Built-in overtemperature control assures safe operation
- Conforms to ASTM D445, D2170, and related specifications for kinematic viscosity testing
|
Designed for high temperature kinematic viscosity determinations of petroleum products,
including ashpalts (bitumens), road oils, and asphalt cements. Features digital solid state
temperature control accurate to within +/-0.01°C (+/-0.02°F) at temperatures of
up to 220°C (450°F). Temperature selection is made by dialing the desired value on
the digital LCD display - bath temperature then stabilizes withing +/-0.5°C (+/-1°F)
of the setpoint. Adjust within +/-0.01°C using the fine tuning control. A selector switch
at the rear of the bath permits selection of either °C or °F temperature scale
setpoint and display. High output chrome plated heaters provide efficient transfer, and a
turbine stirrer system provides turbulence-free circulation. A boost heater circuit can be used
to warm the bath liquid at several times the normal rate. Circulat tap water or refrigerated
coolant through the built-in cooling coil for operation at near ambient temperatures or below.
A temperature limit control circuit automatically interrupts power to the bath when equipment
malfunction or operator error causes bath liquid temperature to exceed 16.7°C (30°F)
above the setpoint or 260°C (500°F). Power is also interrupted at any temperature
if the PT-RTD sensor probe becomes disconnected or malfunctions. Power must then be restored
manually by the operator after checking the cause of the problem. Insulated cabinet has a
safety viewing shield and a chemical resistant cover assembly, which accomodates six round or
rectangular viscometer holders. PyrexTM bath jar is completely
enclosed, and is brightly illuminated for easy viewing of viscometer tubes. |
| Catalog Nubmer | Ordering Information |
| K23420 | High Temperature Viscosity Bath, with rectangular ports, 115V 50/60 Hz |
| K23421 | High Temperature Viscosity Bath, with round ports, 115V 50/60 Hz |
| K23429 | High Temperature Viscosity Bath, with rectangular ports, 220-240V 50/60 Hz |
| K23428 | High Temperature Viscosity Bath, with round ports, 220-240V 50/60 Hz |
|