| 8021 |
| |
As an ammeter |
When measuring
low currents, connect the energizer as shown at left.
Clamp the loop ×5 or ×10 with the transformer jaws of the
clamp meter.
The current to be measured will be indicated as 1/5 or 1/10 of the
value read on the meter. When the direct measurement of the two
conductor line cord is not possible with the clamp meter, clamp the
loop ×1 and read the meter directly. |
|
|
| Connection to AC
Power Outlet |
As a voltmeter |
| First, connect
the energizer as shown at left. Insert one of the voltage test leads
into VOLTS LEAD terminal and the other test lead into VOLTS LEAD
terminal on the reverse side. Then, read the indicated value directly. |
|
|
| Connection to
Appliance under Test |
|
 |
|
|
| Rated value |
ACA-10A max.
ACV-300V max. |
For
use with following models; 2004, 2006, 2007A, 2017, 2027, 2031, 2033
2037, 2412, 2417, 2431, 2608A, 2805, 8113 |
|
|
|