Multi-Trans

8004
 
How to Use
Clamp your instrument around the pick-up coil of the multitran.
Then, clamp the transformer jaws of the multi-tran on the conductor, as shown below.
Multiply the reading of your clamp meter by 10 to obtain the current value measured.
How to Use
8004

Measuring Range 0~1000A AC
Ratio/Range 10 : 1 (input to output)
Accuracy |±3% of full scale
Allowable
Measurement Time
0~1000A (continuous), 1000~1500A (10 minutes max.)
3000A (30 seconds max.)
Conductor Size Ø60mm max. (50 × 75mm)
Frequency Response 50Hz/60Hz
Withstand Voltage 3000V AC for 1 minute
Dimensions 240(L) × 85(W) × 30(D)mm
45(L) × 40(W) × 10(D)mm Output coil
Weight 490g approx.
Accessories 9022(Carrying Case)
For use with
following models *
2002PA, 2002R, 2004(AC only), 2006, 2007A(AC only),
2009A(AC only), 2608A, 2805, 2017, 2027, 2037(AC only),
2412, 2417,8113(AC only), 2031, 2033(AC only),
2431, 2432, 2433, 2433R, 2434
* These Multi-Trans can not be used for leakage current measurement.