| 6300 |
| • |
All necessary Power
Measurements : V, A, W, VA, Var, Wh, VAh, Varh, cos θ, In, Hz. |
| • |
Recording function with
"integration time" selectable from 1 second to 1 hour. |
| • |
Internal non volatile Memory
for non-stop recording up to 10 days. |
| • |
Accepts Removable Compact
Flash Memory up to 128MB for non-stop recording up to 5 years. |
| • |
Supplied with interface
software for downloading data to PC via USB. |
| • |
Four wiring con.gurations : 3
Phase 4 Wires, 3 Phase 3 Wires, single Phase 3 Wire and 2 Wires. |
| • |
Wide screen with back light
Multi-Display system for simultaneous measurements. |
| • |
Double power supply system :
from AC Line and from Alkaline battery with approx. 7 hours of battery
life. |
| • |
Demand function for
Energy-Saving measurements. |
| • |
Designed to Safety Standard
IEC 61010-1 CAT.III 600V. |
|


|
|
|
12 kinds of power measurements |
 |
Voltage (RMS), Current (RMS), active
power, apparent power, reactive power, active energy, apparent energy,
reactive energy, power factor (cos θ), frequency , demand measurement,
current flowing on the neutral line (Only on3 phase 4 wire measurement) |
Regenerative
electric power can be
measured |
 |
Detection of consumption power and
regenerative electric power Regenerative electric power: This is the
electric power which is generated by private power generator, and is
supplied to electric power company. |
The electric power and the power
factor for each phase can be confirmed |
 |
Monitoring of
operation
for each phase. |
Recording
internal can be set between
1 second and 1 hour |
 |
1/2/5/10/15/20/30 second/seconds
1/2/5/10/15/20/30 minute/minutes 1 hour |
Demand
measurement |
 |
Buzzer sounding and backlight
blinking give warning not to exceed the pre-setting demand target value. |
Double
power supply system AC line
and Alkaline size AA battery LR6 : 6 pcs. |
 |
Continuous 7 hours can
be measured by using batteries |
Display
3 different data
simultaneously on large screen. |
 |
|
4 types wiring system |
 |
1 phase - 2 wire (1ch) (2ch), (3ch)
1 phase - 3 wire
3 phase - 3 wire
3 phase - 4 wire |
Direct
communication with PC by USB
connection |
 |
|
The
interface for compact flash card
(CF card) is equipped. |
 |
An external memory up to
128MB or less can be used. |
Demand Function |
 |
|
|
| Measurements
and parameters |
Voltage, Current, Active power, Apparent power, Reactive
power, Active energy, Apparent energy, *Reactive energy, Power factor
(cos θ), Neutral current, Frequency meter. |
| Wiring
connections |
1P
2W, 3P 4W, 3P 3W, 1P 3W |
| Voltage
ranges |
150.0
/ 300.0 / 600.0V AC |
| Voltage
accuracy |
|±0.3%rdg ±0.2%fs [45~65Hz] |
| Current
ranges |
50.00/100.0/200.0/500.0
A AC
(with Clamp sensor MODEL 8125) |
| Current
accuracy |
|±0.3%rdg ±0.2% fs + Clamp sensor
accuracy [at
45~65Hz] |
| Crest
factor |
Voltage
: up to 2.5 Current : up to 3.0 (with 90% fs or less) |
| Frequency
meter range |
40~70Hz |
| Frequency
meter accuracy |
|±3dgt |
| Active
Power accuracy |
|±0.5%rdg ±0.2%fs + Clamp sensor
accuracy [at
45~65 Hz] |
| Accuracy
precondition |
PF=1,
Sine wave, 23ºC±5ºC |
| Effect
of power factor |
Active
power : ±1.0% rdg cos θ=±0.5 (PF=1) |
| Effective
input range |
10~110%
of Rating range of V and A |
| Display
range |
Voltage
: 5~120% of Rating range
Current : 1~120% of Rating range |
| Integration
time for recording function |
1/2/5/10/15/20/30
Seconds 1/2/5/10/15/20/30/60 Minutes |
| Display
update period |
1
second |
| Operating
temperature and humidity ranges |
0~+50ºC,
less than 85% RH (without condensation) |
| Storage
temperature and humidity ranges |
-20~+60ºC,
less than 85% RH (without condensation) |
| Over
load protection |
Voltage
: 720V AC rms
Current : 600A AC rms (with Clamp sensor MODEL 8125) |
| PC
communication Interface |
USB |
| CF
card Interface |
Compact
flash card (Standard type 32/64/128 MB) |
| Safety
standard |
IEC61010-1
CAT.III 600V |
| Power
supply |
AC
Line : 100~240V±10% (50/60Hz)
DC Battery 9V : LR6×6(Battery life approx. 7h) |
| Power
consumption |
10VA
(MAX) |
| Dimension |
175(L)×120(W)×65(D)
mm |
| Weight |
Approx.
800g (including batteries) |
| Accessories |
7141(Test
Lead : 4pcs),
7148(USB Cable),
7169(Mains
cord), 8305(Compact Flash card 32MB),
9125(Carrying bag), PC Software,
Batteries × 6, Quick manual |
| Optional
accessories |
8306(Compact Flash card 64MB).
8307(Compact Flash card 128MB).
8308(CF Card reader).
8124,8125,8126,8127,8128(Load current detection type
clamp sensor).
Wide range of clamp sensor up to 1000A on request.
|
|
|
Set Model |
|
|
|
Consists
of:
MODEL 6300 × 1
MODEL 8125(Φ40) × 3 |
|
 |
|
|
Consists
of:
MODEL 6300 × 1
MODEL 8125(Φ40) × 2 |
|
| |
|
|
|
|
Consists
of:
MODEL 6300 × 1
MODEL 8124(Φ68) × 3 |
|
|
|
|
Consists
of:
MODEL 6300 × 1
MODEL 8124(Φ68) × 2 |
|
| |
|
|
|
|
Consists
of:
MODEL 6300 × 1
MODEL 8126(Φ40) × 3 |
|
|
|
|
Consists
of:
MODEL 6300 × 1
MODEL 8126(Φ40) × 2 |
|
| |
|
|
|
|
Consists
of:
MODEL 6300 × 1
MODEL 8127(Φ24) × 3 |
|
|
|
|
Consists
of:
MODEL 6300 × 1
MODEL 8127(Φ24) × 2 |
|
| |
|
|
|
|
Consists
of:
MODEL 6300 × 1
MODEL 8128(Φ24) × 3 |
|
|
|
|
Consists
of:
MODEL 6300 × 1
MODEL 8128(Φ24) × 2 |
|
| |
|
|
Accessories |
 |
7141(Test Lead : 4pcs) × 1
7148(USB Cable) × 1
7169(Mains Cord) × 1
8305(Compact Flash card 32MB) × 1
9125(Carrying bag) × 1
PC Software × 1
Batteries × 6
Quick manual × 1 |
|
|
 |
|
|