6020 |
6030 |
6020/30 |
| Insulation
Test Specifications |
| Test
Voltage |
125V/250V |
250V/500V |
1000V |
Measuring Ranges
(MΩ) |
0 ~1.999MΩ
1.00 ~19.99MΩ
10.0 ~199.9MΩ |
0
~19.99MΩ
10.0 ~199.9MΩ
100 ~1999MΩ |
| (3 auto ranges) |
| Accuracy |
|±2%rdg ±3dgt,
±10%rdg (on
1000~2000MΩ) |
| Open
Circuit Voltage |
+20% -0% of Rated Test Voltage |
| Rated
Test current |
1mA DC +20%-0% |
| Short
Circuit current |
1.3mA DC approx. |
Effect
of AC Component
of Terminal Voltage |
Within ±10% of reading when 5µF capacitor is
connected in
parallel on insulation test |
| Overload
Protection |
1200V (DC + ACp-p) for 10 seconds |
| Earth
Resistance Test Specifications |
| Measuring
Ranges(Ω) |
0 ~199.9Ω
100 ~1999Ω (2 auto ranges) |
| Accuracy |
|±2%rdg ±3dgt
(at 500Ω auxiliary earth resistance) |
| Measuring
Method |
By constant current inverter 820Hz approx. 2mA approx. |
| Overload
Protection |
200V AC for 10 seconds between measuring terminals |
| Voltage
Test Specifications |
| Measuring
Ranges (V) |
0 ~ 199.9/100 ~ 600V (2 auto ranges) |
| Accuracy |
|±1%rdg ±4dgt |
| Sensing |
True RMS |
| Input
Impedance |
2MΩ |
| Overload
Protection |
900V AC for 1 minute |
| Phase
Check Specifications |
| Measuring
Range |
100 ~ 600V (50Hz/60Hz)
(for checking correct or reverse phase and open phase) |
| General |
| Display |
3 1/2(1999)digit large LCD |
| Response
Time |
Approx. 4 seconds for AC voltage and earth resistance
tests
Approx. 5 seconds for insulation resistance tests. |
| Withstand
Voltage |
5550V AC for one minute |
| Effect
of Drop |
No electrical and mechanical damage shall occur when the
unit
is dropped from a height of 1 m onto the concrete floor. |
| Effect
of Temperature |
Readings shall not differ greater than specified below
when taken at a reference temperature of 23ºC and varied
temperature of
0ºC and 40ºC. AC Voltage 3% ±2 dgt insulation
resistance and earth
resistance 5% ±2 dgt |
| Operating
Temperature Range |
0-40ºC |
| Dimensions |
130 × 238 × 207mm
(main body plus cord reel module)
105 × 238 × 207mm (main body only) |
| Weight |
Approx. 1.6kg (main body only)
Approx. 750g (cord reel module only) |
| Power
Supply |
1.5V LR6 alkaline battery or equivalent × 8 (for
main
body only)
1.5V LR6 alkaline battery or equivalent × 1 (probe only) |
| Safety
Standard |
IEC 61010-1 CAT.III 600V Pollution Degree 2 |
| Optional |
2417(Water Proof Leakage Clamp Meter)
7093(Cord for Extension Probe)
9080(Aluminum Carrying Case) |