| Continuity
Testing |
| Measuring
Ranges |
20/200/2000Ω (Autoranging) |
| Open
Circuit Voltage |
>6V |
| Short
Circuit Current |
>200mA
DC |
| Accuracy |
|±(1.5%rdg+3dgt) |
| Insulation
Testing |
| Measuring
Ranges |
20/200MΩ(Autoranging) |
| Test
Voltage |
250V
500V 1000V DC |
Output
Voltage on
Open Circuit |
250V+40%-0%
500V+30%-0%
1000V+20%-0% |
| Rated
Current |
>
1mA |
| Accuracy |
|±(1.5%rdg+3dgt) |
| Loop
Impedance Testing |
| Rated
Voltage |
230V
AC +10%-15% [50Hz] |
| Voltage
Measuring Range |
100~250V
AC [50Hz] |
| Impedance
Ranges |
20/200/2000Ω |
| Nominal
Test Current |
25A
(20Ω range) 15mA (200Ω range) 15mA (2000Ω range) |
| Accuracy |
20Ω
range ±(3%rdg +4dgt)
200Ω range ±(3%rdg +4dgt)
2000Ω range ±(3%rdg +4dgt) |
| PSC
Testing |
| Rated
Voltage |
230V
AC +10%-15% [50Hz] |
| PSC
Ranges |
200A(15mA
Test Current)
2000A(25A Test Current)
20kA(25A Test Current) |
| Accuracy |
PSC
accuracy derived from measured loop impedance specification and
measured voltage specification |
| RCD
Testing |
| Rated
Voltage |
230V
AC +10%-15% [50Hz] |
| Trip
Current Settings |
RCD
× 1/2 : 10,30,100,300,500,1000mA
RCD × 1 : 10,30,100,300,500,1000mA
RCD × 5 : 10,30,100,300mA (on × 5 ranges max current 1A) |
| Trip
Current Duration |
RCD
× 1/2 × 1: 2000ms
RCD fast: 50ms |
| Accuracy |
Trip
current +10%-0% of test current at 230V
Trip time ±(1%rdg + 3dgt) |
| General |
| Safety
Standard |
IEC61010-1
CAT.III 300V Pollution Degree 2
IEC61557 |
| Withstand
Voltage |
3700V
AC for 1 minute |
| Power
Source |
LR6
(1.5V) × 8 |
| Dimensions |
130(L)
× 183(W) × 100(D)mm |
| Weight |
1100g
approx. |
| Accessories |
*KAPM10
(Molded plug test leads for loop and RCD testing at sockets)
7122(lead for insulation and continuity testing)
KSLP5(external earth probe)
Pouch for Test Leads
Shoulder Strap
Battery LR6 (1.5V) × 8
Instruction Manual |
| Optional
Accessories |
OMA
DIEC (Distribution board or lighting circuit test leads for
LOOP/PSC/RCD testing) |