Horiba S-316 Solvent

S-316
  • The OCMA-350 uses the highly effective, environmentally-safe S-316 extraction solvent to extract the oil components from oily water samples, soil samples, or product surfaces. The extract is analyzed using IR absorbance, a non-dispersive infrared spectrophotometric technique which is specific to hydrocarbons such as oil.
  • The OCMA-350 measures absorption in the 3.4 to 3.5 micrometer range. The two graphs at the right show the absorption spectra of (1) petroleum and (2) HORIBA S-316 solvent. All hydrocarbons, including oils, absorb infrared radiation at about 3.4 to 3.5 micrometers. As a result, the unit can measure any hydrocarbons in the extraction solvent quickly and accurately, with no distortion of values due to presence of the solvent.
  • HOROBA's S-316 Solvent can be recycled with the aid of the optional SR-300 Solvent Reclaimer. Recycling the solvent not only cuts your solvent costs, but also helps protect the environment.

graph
graph





Model SR-300 Solvent Reclaimer


  • Highly efficient, the SR-300 can reduce your per test solvent cost by up to 90%. This optional unit, designed especially for reclaiming S-316 solvent, features a double column of activated carbon and activated aluminum. It has a large filtering capacity, is easy to operate, and requires no electricity.
SR-300 External dimensions:
200(W) x 200(D) x 600(H) mm
7.9(W) x 7.9(D) x 23.6(H) in




Routine analysis of oil residuals

  • OCMA-350 analyzer simplifies measurement of oil in water or soil for a variety of applications. Use this precision instrument for surveying water quality and hazardous waste sites, industrial wastewater monitoring, post-cleaning discharge analysis, and measuring adherent oil residuals on textiles and metal parts.
  • Use S-316 solvent to quantitatively extract sample. The oil / solvent solution is then simply transferred to the OCMA-350 analyzer for single-button measurement. Analysis is based on infrared (IR) spectral data, with peak integration (at approximately 3.4 ìm) to determine oil concentration. S-316 solvent is non-absorbant at this IR wavelength, so only oil is measured. Accurately measures oil down to 0.1 ppm. Auto-calibrates after initial standard reading.
  • Use built-in time stamping to document results. Read results on LCD or transfer data using parallel printer port or to computer via RS-232. S-316 solvent can be recycled using Solvent Reclaimer SR-300 (82900-20), sold separately below.




S-316 MSDS (Material Safety Data Sheet)



Name S-316,CLEANING COMPOUND,100690 MSDS chxfl
HORIBA
FSC 6850

MSDS Safety Information
FSC: 6850
NIIN: 01-456-3617
MSDS Date: 01/01/1997
MSDS Num: CHXFL
Product ID: S-316,CLEANING COMPOUND,100690
MFN: 01
Responsible Party
Cage: 53595
Preparer's Name: UNKNOWN
Review Ind: Y
Published: Y
Item Description Information
Item Manager: S9G
Item Name: CLEANING COMPOUND,SOLVENT
Specification Number: NONE
Type/Grade/Class: NONE
Unit of Issue: CO
Quantitative Expression: 10000000015KG
UI Container Qty: 0
Type of Container: CONTAINER
Ingredients
Cas: 9002-83-9
RTECS #: KM6555000
Name: CHLOROTRIFLUOROETHYLENE TELOMER/POLYCHLOROTRIFLUOROETHYLENE
% Wt: UNKNOWN
Other REC Limits: NONE RECOMMENDED
OSHA PEL: NOT ESTABLISHED
ACGIH TLV: NOT ESTABLISHED
Health Hazards Data
LD50 LC50 Mixture: LD50 (ORAL) ANDgt; 52,000 MG/KG
Route Of Entry Inds - Inhalation: NO
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: TARGET ORGANS: NONE. ACUTE- NONE. CHRONIC- NONE.
Explanation Of Carcinogenicity: NONE
Signs And Symptions Of Overexposure: NONE
Medical Cond Aggravated By Exposure: UNKNOWN
First Aid: CALL PHYSICIAN IF SYMPTOMS PERSIST. EYE: IMMEDIATELY FLUSH WITH
WATER FOR 15 MINUTES. HOLD EYELIDS OPEN. SKIN: WASH WITH SOAP ANDamp; WATER.
INHALED: REMOVE TO FRESH AIR. PROVIDE CPR/OXYGEN IF NEEDED. ORAL: CALL A
PHYSICIAN/POISON CONTROL CENTERIMMEDIATELY.
Handling and Disposal
Spill Release Procedures: WEAR PROTECTIVE EQUIPMENT. VENTILATE AREA. ABSORB ON
SAND, VERMICULITE OR USE PUMP. PLACE IN AN APPROPRIATE CONTAINER FOR
DISPOSAL. WASH CONTAMINATED SPILL AREA WITH DETERGENT AND WATER. DO NOT
CONTAM INATE ENVIRONMENT.
Neutralizing Agent: NOT RELEVANT
Waste Disposal Methods: DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS. CONTRACT WITH A LICENSED WASTE DISPOSAL FACILITY. REUSING IS RECOMMENDED.
Handling And Storage Precautions: STORE AWAY FROM INCOMPATIBLE MATERIALS.
Other Precautions: WASH THOROUGHLY WITH SOAP AND WATER AFTER HANDLING AND
BEFORE EATING, DRINKING, SMOKING. KEEP OUT OF REACH OF CHILDREN. DO NOT TAKE
INTERNALLY. DO NOT GET IN EYES OR ON SKIN.
Fire and Explosion Hazard Information
Flash Point Text: NONE
Lower Limits: NOT RELEVANT
Upper Limits: NOT RELEVANT
Extinguishing Media: WATER SPRAY, CARBON DIOXIDE, FOAM OR DRY CHEMICAL FOR
SURROUNDING FIRE. USE WATER SPRAY TO COOL FIRE EXPOSED CONTAINERS.
Fire Fighting Procedures: WEAR PROTECTIVE CLOTHING AND NIOSH-APPROVED
SELF-CONTAINED BREATHING APPARATUS WITH FULL FACEPIECE OPERATED IN POSITIVE PRESSURE MODE.
Unusual Fire/Explosion Hazard: TOXIC GASES MAY BE FORMED.
Control Measures
Respiratory Protection: IF ENGINEERING CONTROLS DO NOT MAINTAIN AIRBORNE
CONCENTRATIONS TO AN ACCEPTABLE LEVEL, A NIOSH-APPROVED ORGANIC VAPOR
RESPIRATOR MUST BE WORN. A PROGRAM SHOULD BE INSTITUTED TO ASSURE COMPLIANCE
WITH OSHA STANDARD 29 CFR 1910.134.
Ventilation: GENERAL MECHANICAL VENTILATION IS ADEQUATE FOR NORMAL USE. LOCAL
EXHAUST IS RECOMMENDED FOR CONFINED AREAS.
Protective Gloves: LATEX FOR REPEATED/PROLONGED CONTACT
Eye Protection: SAFETY GLASSES/GOGGLES RECOMMENDED
Other Protective Equipment: EYE WASH STATION, SAFETY SHOWER, PROTECTIVE CLOTHING
Work Hygienic Practices: OBSERVE GOOD INDUSTRIAL HYGIENE PRACTICES AND RECOMMENDED PROCEDURES.
Physical/Chemical Properties
HCC: N1
NRC/State LIC No: NOT RELEVANT
B.P. Text: 273F,134C
M.P/F.P Text: UNKNOWN
Decomp Text: UNKNOWN
Vapor Pres: 11.5 @ 77F
Vapor Density: UNKNOWN
Spec Gravity: 1.75
Viscosity: UNKNOWN
Evaporation Rate ANDamp; Reference: UNKNOWN
Solubility in Water: INSOLUBLE
Appearance and Odor: CLEAR LIQUID - SLIGHT ODOR
Corrosion Rate: UNKNOWN
Reactivity Data
Stability Indicator: YES
Stability Condition To Avoid: NONE
Materials To Avoid: METALS SUCH AS SODIUM, POTASSIUM, ALUMINUM; AMINES, LIQUID
FLUORINE, LIQUID CHLORINE TRIFLUORIDE
Hazardous Decomposition Products: CARBON MONOXIDE, CARBON DIOXIDE, HYDROGEN
CHLORIDE, HYDROGEN FLUORIDE, CARBONYL HALIDES, FLUORINE, CHLORINE MAY BE FORM.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
Toxicological Information Ecological Information MSDS Transport Information Regulatory Information Other Information Transportation Information
Responsible Party Cage: 53595
Trans ID NO: 137286
Product ID: S-316,CLEANING COMPOUND,100690
MSDS Prepared Date: 01/01/1997
Review Date: 10/20/1998
MFN: 1
Radioactivity: NOT RELEVANT
Net Unit Weight: 3.3 LBS
Multiple KIT Number: 0
Review IND: Y
Unit Of Issue: CO
Container QTY: 0
Type Of Container: CONTAINER
Additional Data: WARNING STATEMENT: NONE, PER MSDS.
Detail DOT Information
DOT PSN Code: ZZZ
DOT Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
Detail IMO Information
IMO PSN Code: ZZZ
IMO Proper Shipping Name: NOT REGULATED FOR THIS MODE OF TRANSPORTATION
Detail IATA Information
IATA PSN Code: ZZZ
IATA Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
Detail AFI Information
AFI PSN Code: ZZZ
AFI Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
HAZCOM Label
Product ID: S-316,CLEANING COMPOUND,100690
Cage: 53595
Date Of Label Review: 10/20/1998
Status Code: C
Label Date: 10/20/1998
Year Procured: 1998
Hazard And Precautions: ?????



       For more information, please contact ExpotechUSA       
       Shipping Address                  Mailing Address                           Phone                   Web     
10700 Rockley Road
10700 Rockley Road
281-496-0900 [voice] Click here to e-mail us
Houston, Texas 77099
Houston, Texas 77099
281-496-0400 [fax]   
  ExpotechUSA's HomePage