Traceable® Bench Conductivity Meter Complete
Description
Turn on, insert probe, read results
Fulfill all official lab analysis regulations and reagent-grade water
standards for CAP, ASTM, NCCLS, and ACS by using the Bench Conductivity
Meter. Simply turn on, insert probe into solution, and read accurate
results. Unit automatically encompasses all ranges and selects the most
appropriate for the current reading. Disable the auto-range function
when user-defined ranges are desired. Control allows user to calibrate
to solution standards. Ranges are: 0.01 to 200,000 micromhos
(microsiemens), 0.001 to 20.000 megohms, 0.1 to 20,000 dissolved
solids/parts per million, 2.0 to 42.0 salinity (oceanographic units).
Accuracy is ±0.3%.
Traceable to NIST for accuracy
To assure accuracy an individually serial-numbered Traceable®
Certificate is provided from our ISO 17025 calibration laboratory
accredited by A2LA. It indicates traceability to standards provided by
NIST (National Institute of Standards and Technology). State-of-the-art
microcomputer processor and unique software program allow four
calibration points to ensure complete accuracy over the entire range.
Readings are displayed in conductivity (micromhos/cm) (microsiemens),
resistivity (megohms), total dissolved solids (milligrams per liter),
salinity (oceanographic units), concentration (user specified units),
and temperature (Celsius/Fahrenheit). K factor may be adjusted to match
each probe. Specifically designed to measure conductivity in water
analysis, biology, chromatography, food, and PC board rinsing.
RS-232 serial output
Computer output may be downloaded to a data logger or computer for
analyzing or reporting at a later time. Makes hard copy results a
breeze–no more hand-scrawled notes to decipher. Supplied probe contains
platinum electrodes and a solid-state thermistor for automatic/manual
temperature compensation. Readings are automatically referenced to the
international standard of 25°C. Exclusive “temperature compensation
disable function” fulfills USP-NF (United States Pharmacopoeia,
National Formulary, 645 Conductivity Measurement) requirement.
ABS plastic housing withstands the roughest lab environments.
Unit comes with 115 VAC adapter, probe replatinizing current, a probe
holder arm, battery, and Traceable® Certificate. Glass Probe is
5-1/4 x ½ inches diameter with a cable length of 59 inches. Size
is 8-1/4 x 6 x 3-1/2 inches and weight is 1-1/2 pounds. Replacement
battery Cat. No. 1112.
Control Cat. No. 4163
Traceable® Bench Conductivity Meter
| Performance
Chart |
Ranges in Micromhos
(mircosiemens)/TD> |
0.01 to 20.00
0.1 to 200.0
1 to 2000
10 to 20000
100 to 200000 |
| Ranges in Megohms |
0.001 to 2.000
0.01 to 20.00 |
| Ranges in Dissolved Solids/Parts Per Million |
0.1 to 20.00
1 to 200
10 to 2000
100 to 20000
|
| Accuracy |
±0.3% |
| Cat. No. |
Accessories. |
| 4062 |
Replacement Conductivity Probe, Glass, K=1,
Probe range is from 0.05 to 200,000 micromhos.
|
| 4061 |
Accessory Conductivity Probe- Unbreakable
Epoxy, K=1
Probe range is from 1.0 to 200,000 micromhos.
|
| 4054 |
Accessory Conductivity Glass Flow-Through
Cell, with volume of 4 ml, K=1 |
| 4055 |
Accessory Micro-Sampler/Flow-Through Cell,
with volume of 2 ml, K=0.2 |
|